Purpose
To determine general thermogelation speed and morphology
upon gelation of mixed AK019 and AK012 gelation system.
Materials and Methods
PLGA-PEG-PLGA LG 50:50 (w:w) (Mn ~1,000:1,000:1,000 Da) PolyVivo
AK012 Lot#50904ELH
PLGA-PEG-PLGA LG 50:50 (w:w) (Mw ~1,500:1,500:1,500 Da) PolyVivo
AK019 Lot#50413BAK
Methylene Blue
Hotplate
Camera
Methods
PolyVivo block copolymers catalog numbers AK019 and AK012
were both in cold water overnight to form 20% w/v solutions. A contrast dye
solution was generated by dissolving methylene blue at a concentration of
2 mg/ml in 0.1% HOAc. A quantity of 0.75ml of 20% w/v AK019 solution was
combined with 0.25 ml of AK012 solution and 10 µL of 2mg/ml methylene blue was
added to the solution for visibility. This solution was then pipetted onto a
hot-plate and images were recorded for gelation speed.
Results/Discussion
A common question regarding thermogels is how ‘fast’ do they
gel upon warming. A large volume of thermogel solution is a relatively poor
example because the ‘bottle-neck’ to gelation speed is how quickly the mass of
water’s temperature can be increased in order to effect gelation. In the sense
of an injectable depot, the cold-gel solution is forced through a fine-gauge
needle into a warm body. This provides a relatively high surface area for heat
transfer and, in this condition, the gel reaches body temperature more rapidly
than a typical in-vitro type test such as placing a glass vial full of gel in
an incubator as the incubator must slowly warm the vial itself and then the
contents to 37 °C to achieve gelation. As can be seen in the video below, when
spread out into a fine layer more representative of actual in-vivo conditions, the gel-speed is quite rapid happening in under a few seconds.