PolySciTech
division of Akina, Inc. (www.polyscitech.com)
provides a wide variety of block copolymers including PLGA-PEG-PLGA. Recently, PLGA-PEG-PLGA
from Akina, Inc. was purchased (PolyVivo Catalog#: AK032 and Catalog#: AK017)
and used for testing Albumin interaction with these nanoparticles. They
confirmed the importance of PEG’s steric hinderance for preventing protein adsorption
to nanoparticle. Read more: Geskovski, Nikola, Simona Dimchevska, Rozafa
Koliqi, Gjorgji PetruĆĄevski, Marina Chacorovska, Sonja Ugarkovic, and Katerina
Goracinova. "A spectroscopic insight into the albumin structure on the
nano-bio interface." Your hosts Macedonian Pharmaceutical Association and
Faculty of Pharmacy, Ss Cyril and Methodius University in Skopje: 367.
https://www.researchgate.net/profile/Irina_Mladenoska/publication/304577752_Effect_of_glucose_concentration_on_glucose_oxidase_activity_in_a_minimal_model_must/links/5773d3e908aeb9427e241721.pdf#page=367
“Synopsis (* quotes compiled from paper sections): It
is becoming clear that, when placed into a biological environment,
nanoparticles initiate a cascade of interactions with the biomacromolecules
resulting in the formation of the ‘protein corona’ (a layer(s) of proteins adsorbed
on the nanoparticles surface) (Monopoli et al., 2011). These interactions can
alter the secondary structure of the adsorbed proteins promoting instability
and/or exposure of new epitopes at the protein surface, thus giving rise to
unexpected biological responses (Calzolai et al., 2010). PLGA-PEO-PLGA (Mw
148KDa and Mw 22KDa) was purchased from Akina Inc (USA). Nanoparticle
formulations were prepared from PLGAPEO-PLGA (Mw 70,000:8,000:70,000Da) – NP1
and PLGA-PEO-PLGA (Mw 6,000:10,000:6,000Da) – NP2, using the nanoprecipitation
method, as described previously All samples were diluted to concentration of
2mg/ml and subsequently 1ml from each formulation was mixed with 1ml of 2mg/mL
BSA solution in phosphate buffer (pH 7.4). The NP dispersions with BSA were
incubated for 1h at 37°C in a water bath with horizontal shaking at 100 min- 1.
After the incubation, the samples were concentrated to 1mL using
ultrafiltration tubes with pore size of 1000 kDa, and washed with phosphate
buffer pH 7.4. Blank (BSA free) and control sample (without nanoparticles) were
also used in the experiment. The amount of adsorbed BSA was indirectly
quantified using the Bradford protein assay. The results from the quantitative
BSA adsorption studies revealed that 24.6±1.9 and 13.1±0.9% of BSA were
adsorbed on the surface of NP1 and NP2, respectively. The results unambiguously
point to the effect of the hydrophilic outer nanoparticle layer as a steric
barrier for nanoparticle-BSA interactions.”
No comments:
Post a Comment